Why is my furnace blowing cold air? A fan setting, restricted airflow, ignition issue or safety control can all be involved. Notice whether the air is cool between heating cycles, whether it starts warm and then turns cool, or whether the burners light and shut off.
For a Missouri homeowner, begin with settings and airflow you can check safely. Do not open the furnace cabinet or bypass a safety switch.
If these checks do not solve it, schedule furnace service.
Check the thermostat fan setting
On many systems, a fan set to ON can keep the blower moving air between heating calls. That air may feel cool because the burners are not heating it at that moment. AUTO usually runs the blower during a heating cycle. Check your thermostat manual before changing settings because controls differ.

Check the filter and airflow
A heavily loaded filter or blocked return can reduce airflow. Check the filter and replace it if it is dirty and due for service. Make sure supply registers and return grilles are not covered by furniture, rugs or boxes.
If the furnace starts warm, then the air turns cool while the blower keeps running, restricted airflow is one possible cause. A furnace limit control can stop the burners when the unit gets too hot. If changing a filter and clearing airflow does not help, have a technician inspect the system.

If the burners light and then shut off
A furnace that lights briefly and shuts down may have an ignition or flame-sensing problem. A dirty flame sensor is one possible cause, but it is not the only one. See how a furnace flame sensor works for more detail. If the problem continues, schedule a technician rather than repeatedly resetting the furnace.
Consider the condensate drain on a high-efficiency furnace
Some high-efficiency furnaces produce condensate that drains through tubing. A blocked drain or a tripped safety switch can stop a heating cycle. If you see water near the furnace or the unit will not start, leave the panels and switches alone and arrange a professional inspection.
Stop if you smell gas
If you smell gas, leave the home and call the gas utility or emergency services from outside. Do not troubleshoot the furnace or operate electrical switches inside.
When to call for furnace repair
Arrange service if the thermostat and airflow checks do not resolve the issue, the furnace will not stay lit, a safety switch keeps tripping, or you see water around the unit. Schraer provides furnace repair and service for homes in Warrenton, Montgomery County and the St. Louis Westplex.
Frequently asked questions
Why does a furnace in Warrenton blow cool air between heating cycles?
If the thermostat fan is set to ON, the blower may circulate room air when the burners are off. Check the thermostat manual and compare the ON and AUTO settings.
What does warm air followed by cold air mean in a Missouri home?
Restricted airflow is one possible cause. Check a dirty filter and blocked registers or returns. If the pattern continues, have a technician inspect the furnace.
Why does my furnace light and shut off in St. Charles County?
An ignition or flame-sensing issue can cause a short heating cycle, but other faults can produce similar symptoms. Stop repeated resets and arrange a professional diagnosis.
Can a dirty filter make a furnace blow cold air in the St. Louis Westplex?
A clogged filter can restrict airflow and contribute to overheating or a burner shutdown. Replace a dirty filter that is due, and seek service if the problem remains.
What should I do if I smell gas near my furnace in Warren County?
Leave the home and call the gas utility or emergency services from outside. Do not continue troubleshooting indoors.
Schedule a service visit
If the thermostat and filter checks do not restore heat, Call 636-200-3276, visit schraerair.com, or schedule service. Schraer Heating & Air Conditioning serves the St. Louis Westplex. St. Charles County license M2685A. St. Louis County license HVR5609.